    Feature:
     
    Specially user for animal,anesthesia ventilator,could widely apply in vet hospital,animal R&D institute,university laboratory,animal clinicanimal zoo,etc,it can match any brand anesthesia machine to use
    1. Compact and salve the space.
    2. Light and easy to move,save animal hospital cost.
    3. automatically Calculation by  weight to the other parameter
    4. With breathing mode PCV mode, achieve the breathing automatically,
    5. Assure the animal more comfortable.
    6. With big animal bellow and small animal bellow,specially for animal use
    7. The gas source pipeline take the high precious gas source,no leakage forever.
    8. HD TFT Touch screen,perfect technology,touch at key to Set parameter ,very easy and simple to operate.
    9. Build in battery could continue two more hours in case of power failure
    10. Matching with different brand veterinary anesthesia machine
     
     
    Specification
     
    Basic description
    Parameter Description
    Display 9 inch TFT, with touch screen.
    Drive gas Gas type O2 or Air
    Inlet pressure 280-600 kPa.
    Max flow ≤ 120 L / min.
    Operating Mode VCV,PCV,SPONT,ManualDemo
    Waveform Waveform: 
    Pressure,Flow-rate,Volume
    Loop:PV loop, PF loop,FV loop
    Safety Pressure System pressure does not exceed 6 KPa.
    Battery Type Li-ion,work time more than 2 hours
     
     
    Parameters setting range
    Parameter description
    Tidal volume Range: 20 - 1500ml; Increment: 1 mL;
    Respiratory rate Range: 1 ~ 100 bpm; 
    Inspiratory time Range: 0.1 ~ 10.0 s
    Respiratory ratio Range: 9.9:1 to 1:9.9
    Percentage of inspiratory pause Range: 0 to 50%
    PEEP Range: OFF, 3 ~ 20 cmH2O
    Pressure Support Range: 0 ~ 60 cmH2O
    Pressure Control Range: 5 ~ 60 cmH2O
    Flow trigger Range: 0.5 ~ 20L/min
    Pressure Trigger Range: -1 ~ -20 cmH2O
    PSV Insp Termination Level 25%.
     
     
    Monitored parameters
    Parameter Description
    Inspiratory tidal volume Range: 0 ~ 2500 mL
    Expiratory tidal volume Range: 0 ~ 2500 mL
    Minute ventilation Range: 0 ~ 60 L / min
    Spontaneous minute ventilation Range: 0 ~ 60 L / min
    Respiratory rate Range: 0 ~ 100 bpm
    Spontaneous breathing frequency Range: 0 ~ 100 bpm
    Respiratory ratio Range: 9.9:1 to 1:9.9
    Peak airway pressure Range: 0 ~ 100 cmH2O
    Mean airway pressure Range: 0 ~ 100 cmH2O
    PEEP Range: 0 ~ 100 cmH2O
    Inspiratory plateau pressure Range: 0 ~ 100 cmH2O
    FiO2(optional) Range: 15 to 100%
     
    Alarm settings
    Alarm type Range
    Tidal volume High 0 ~ 2000 mL, OFF
    Low 0 ~ 1500 mL
    Minute ventilation High 1 ~ 99 L
    Low 0 ~ 98 L
    Respiratory rate High 1 ~ 100bpm
    Low 0 ~ 99 bpm
    FiO2(optional) High 19 ~ 100%
    Low 18 ~ 99%
    Airway pressure High 6 ~ 99 cmH2O
    Low 0 ~ 9 8 cmH2O