We use cookies to improve your online experience. By continuing browsing this website, we assume you agree our use of cookies.
Categories

Non-Invasive High Flow Nasal Cannula Oxygen ICU Ventilator YSAV-OH70C

Model: YSAV-OH70C
YSAV-OH70C Non-Invasive ICU Humidified High Flow Nasal Cannula Oxygen Ventilator
  • ModelYSAV-OH70C
  • BrandYSENMED
  • PriceGet Price
  • MOQ1
  • Ship FromFrom Guangzhou, China
  • ShippingAny shipping terms convenient for customers
  • -
    +
    Categories:Respirators / Ventilators
    Share:
    Description Get Price Review


    As high flow nasal cannula is the main respiratory assist segment of most severe coronavirus pneumonia patients, the YSAV-OH70C non-invasive ventilator is the perfect option for severe COVID-19 patients.
    Main Features
    Product Name: Heated humidified high flow nasal cannula oxygen therapy device (HFNC) Ventilator
    Model: YSAV-OH70C
    Dimensions: 340×228×162mm
    Weight: 3.3kg
    Flow Settings Adult Mode: 10L/min-70L/min, Children Mode: 2L/min-25L/min
    Oxygen Concentration: 21%-100% (adjustable by 1%)
    Temperature: 31 ºC-37ºC (adjustable by 1ºC )
    Treatment Interfaces: Children nasal cannula, Nasal cannula, Tracheostomy, Face mask
    Step Length: 10L/min-70L/min (increments of 5L/min), 2L/min-25L/min (increments of 1L/min)
    Trend Review: 1days, 3days, 7days
    Real-Time Monitoring: Parameter Flow, Temperature, O2 concentration, Treatment time
    Applicable departments: Respiratory, ICU, Emergency Department, Neurology, Neurosurgery, Geriatrics, Cardiothoracic Surgery, Cardiology, Pediatrics
    Precise Oxygen Concentration Control
    The YSAV-OH70C utilizes high-precision proportional valve controls oxygen concentration, no external manual adjustment is required
    21% -100% oxygen concentration adjustment range, 1% oxygen concentration adjustment accuracy
    When the flow rate changes, the proportional valve of the air-oxygen mixer is adjusted according to the software setting to ensure a constant oxygen concentration
    Built-in accurate oxygen concentration monitoring module can realize the accurate display of oxygen concentration index without loading consumables such as the oxygen battery
    Intelligent Temperature and Humidity Control System
    The YSAV-OH70C can provide gas close to the core temperature of the human body (37 ℃) and 100% relative humidity (44mg / L), so that the mucus cilia cleaning function is in the best state
    Temperature control: 21 ℃-37 ℃, adjustable in seven gears
    Adjust heating and humidification system to ensure accurate and constant temperature and humidity
    70L / min high flow rate to meet more clinical needs
    2-70L / min flow adjustment range to meet more clinical needs
    Can effectively wash away the physiological anatomical dead space and prevent carbon dioxide re-inhalation
    Built-in multi-point flow sensor to ensure an accurate and stable flow
    Fully humidified gas and suitable temperature
    A Comfortable Treatment Experience for Patients
    Imported special silicone stuffy nose
    No pressure, patients are well tolerated and highly compliant
    Intelligent temperature and humidity control system
    Minimizes the gas temperature and humidification effect on the patient end, improves patient comfort and prevents condensation
    Provides four different patient interfaces
    Suitable for a variety of environments and clinical needs
    Innovative Safe-Airway Design – No Disinfection Required
    The YSAV-OH70C uses a unique safety design- patient gas does not return to the host, so the machine does not need to be disinfected to prevent cross-infection
    Original trend review function, full control of the patient’s situation
    Review temperature data, humidity, flow rate and oxygen concentration for the previous 1-7 days
    Disposable heating water box and heating pipeline
    Disposable supplies, no need for disinfection, to prevent cross-infection
    The water tank can add water automatically without manual operation
    4.3-inch large color screen & multi-function knob design
    Multiple treatment data can be set and monitored, the operation is more convenient, and the clinical efficiency is improved
    Integrated trolley & boom
    It is convenient for bed treatment and movement in the department and can be operated with one hand

    YSAV-OH70C Non-Invasive Ventilator Specifications
     
    Parameters   Description
    Flow settings   Adult Mode: 10L/min-70L/min Children Mode: 2L/min-25L/min
    Oxygen concentration   21%-100% (adjustable by 1%)
    Temperature   3lX:-37dC (adjustable by 1eC)
    Treatment interfaces   Children nasal cannula, Nasal cannula, Tracheostomy, Face mask
    Step Length   10L/min-70L/min (increments of 5L/min), 2L/min-25l_/min(increments of 1L/rr
    Trend review   1 days, 3 days, 7days
    Real time monitoring parameter Flow, Temperature, O2 concentration, Treatment time
    Dimensions   340*228*162mm
    Weight   3.3kg
    Write down your demand below and we will contact you within 24h!