We use cookies to improve your online experience. By continuing browsing this website, we assume you agree our use of cookies.
Categories

15 inch Touch Screen Medical ETCO2 Multi Parameter Monitor YSPM90D

Model: YSPM90D
  • ModelYSPM90D
  • BrandYSENMED
  • PriceGet Price
  • MOQ1
  • Ship FromFrom Guangzhou, China
  • ShippingAny shipping terms convenient for customers
  • -
    +
    Categories:Patient Monitors
    Share:
    Description Get Price Review


    1.15" high resolution color TFT LCD display;
    2.13 Type Arrhythmic Analysis, Multi_Lead ECG Waveforms Display in Phase, Real time S_T segment analysis, pacemaker detection Drug calculation and titratiotable;
    3. Efficient resistance to interference of defibrillator and electrosurgical cautery;
    4. SPO2 can testing for 0.1% Weak;
    5. RA-LL impedance Respiration;
    6. Trend Coexist Display;
    7. OxyCRG DyNamic View Display;
    8. Bed to Bed view Display;
    9. Networking capacity ;
    10. Options of printing, IBP, VGA and EtCO2;
    11. UP to 4 hours working capacity of built_in rechargeable battery;
    12.15" high resolution color TFT LCD display;
    13. Large volume of tabular and graphic trends information storage and easy to recall;
    14. Anti-ESU, anti- defibrillator;
    15. Capture dynamic waveforms.

    Technical specification
    Specifications:

    ECG

    Lead Mode: 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)
    Lead selection: I, II, III, avR, avL, avF, V,
    Waveform: 2 ch
    Lead mode: 3 Leads ( R, L, F or RA, LA, LL)
    Lead selection: I, II, III,
    Waveform: 1 ch
    Gain: ′2.5mm/mV, ′5.0mm/mV, ′10mm/mV, ′20mm/mV, auto
    HR and Alarm
    Range
    Adult: 15 ~ 300 bpm
    Neo/Ped: 15 ~ 350 bpm
    Accuracy : ± 1% or ± 1bpm,which great
    Resolution: 1 bpm
    Sensitivity: > 200 (uV P-P)
    Differential Input Impedance: > 5 MΩ
    CMRR
    Monitor: > 105 dB
    Operation: > 105 dB
    Diagnosis: > 85 dB
    Electrode offset potential: ±300mV
    Leakage Current: < 10 uA
    Baseline Recovery: < 3 S After Defi.
    ECG Signal Range: ±8 m V ( Vp-p )
    Bandwidth
    Surgery: 1 ~ 15 Hz
    Monitor: 0.5 ~ 35 Hz
    Diagnostic: 0.05 ~ 100 Hz
    Calibration Signal: 1 (mV p-p), Accuracy:±5%
    ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV
    ARR Detecting
    Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC,
    TACHY, BRADY, MISSED BEATS, PNP, PNC
    Alarm: Available
    Review: Available

    RESPARATION

    Method: Impedance between R-F(RA-LL)
    Differential Input Impedance: >2.5 MΩ
    Measuring Impedance Range: 0.3~5.0Ω
    Base line Impedance Range: 0 – 2.5 KΩ
    Bandwidth: 0.3 ~ 2.5 Hz
    Resp. Rate
    Measuring and Alarm Range
    Adult: 0 ~ 120 rpm
    Neo/Ped: 0 ~ 150 rpm
    Resolution: 1 rpm
    Accuracy : ±2 rpm
    Apean Alarm: 10 ~ 40 S

    NIBP

    Method: Oscillometric
    Mode: Manual, Auto, STAT
    Measuring Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min)
    Measuring Period in STAT Mode: 5 Min
    Pulse Rate Range: 40 ~ 240 bpm
    Alarm Type: SYS, DIA, MEAN
    Measuring and alarm range
    Adult Mode
    SYS: 40 ~ 270 mmHg
    DIA: 10 ~ 215 mmHg
    MEAN: 20 ~ 235 mmHg
    Pediatric Mode
    SYS: 40 ~ 200 mmHg
    DIA: 10 ~ 150 mmHg
    MEAN:20 ~ 165 mmHg
    Neonatal Mode
    SYS: 40 ~ 135 mmHg
    DIA:10 ~ 100 mmHg
    MEAN:20 ~ 110 mmHg
    Resolution Pressure:1mmHg
    Accuracy Pressure Maximum Mean error: ±5mmHg
    Maximum Standard deviation: ±8mmHg
    Overpressure Protection
    Adult Mode: 297±3 mmHg
    Pediatric Mode: 240±3 mmHg
    Neonatal Mode: 147±3 mmHg

    SpO2

    Measuring Range: 0 ~ 100 %
    Alarm Range: 0 ~ 100 %
    Resolution: 1 %
    Accuracy : 70% ~ 100% ±2 %
    0% ~ 69% unspecified
    Actualization interval: about 1 Sec.
    Alarm Delay: 10 Sec.
    Pulse Rate
    Measuring and Alarm Range: 20~300bpm
    Resolution: 1bpm
    Accuracy : ±2bpm

    TEMPERATURE
    Channel: 2
    Measuring and Alarm Range: 0 ~ 50 °C
    Resolution: 0.1°C
    Accuracy : ±0.1°C
    Actualization interval: about 1 Sec.
    Average Time Constant:<10 Sec.


    IBP
    Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2
    Measuring and alarm range
    ART: 0 ~ 300 mmHg
    PA: -6 ~ 120 mmHg
    CVP/RAP/LAP/ICP: -10 ~ 40 mmHg
    P1/P2: -10 ~ 300 mmHg
    Press Sensor
    Sensitivity: 5 uV/V/mmHg
    Impedance: 300-3000Ω
    Resolution: 1 mmHg
    Accuracy : ±2% or ±1mmHg, which great
    Actualization interval: about 1 Sec


    tandard: ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature
    Optional: Nellcor SpO2, EtCO2,IBP, Touch screen, Thermal Recorder,Wall mount, Trolley, Central station,HDMI

     

    Write down your demand below and we will contact you within 24h!

    1/3
    X